Our website uses cookies to better meet your requirements. Proper configuration of browser options allows you to block or remove cookies but can also cause the site to not function properly or even at all. By continuing to use the site, with no change to your browser settings, you agree to the use of cookies.
Learn about our Privacy Policy for cookies and other similar technologies.

Thermostatic valve bodies for single pipe heating systems

The E-Z System is a universally useable valve for all radiators with a two point connection in single and two-pipe heating systems. the single pipe valve with immersion pipe is used for radiators with lateral single point connection. Centre-to-centre distance of pipe connections 58 mm.

Product Information

The E-Z System is a universally useable valve for all radiators with a two point connection in single and two-pipe heating systems. the single pipe valve with immersion pipe is used for radiators with lateral single point connection. Centre-to-centre distance of pipe connections 58 mm.

E-Z System

Technical description

The HEIMEIER E-Z System is a universally useable valve for all radiators with a two point connection in single and two-pipe heating systems. The system consists of an E-Z distributor, thermostatic valve body, alternatively with axial, angle or straight form with bend nipple, as well as precision steel pipe and compression fittings.

Pipe connector G3/4, with compression fittings for plastic, copper, precision steel, or multi-layer pipes.

For the HEIMEIER E-Z System, use only the accompanying, labeled HEIMEIER compression fittings (label e. g. 15 THE).

In single pipe operation, the mass flow to the radiators can be set anywhere in the area between 30–60%. Factory settings: 35% to the radiator.

The distributor can be reset by turning the regulating cone to the left as far as it will go to two-pipe operation (100% mass flow through the radiator, by-pass closed).

By turning the regulating cone all the way to the right, the return is shut off, the supply by closing the thermostatic valve body, as a result of which the radiator is detachable without emptying the unit. The by-pass stays opened in single pipe operation regardless of the shut-off, so that the circulation of the circularpipeline is not interrupted.

The flow direction marked on the E-Z distributor should be followed, since the flow through the radiator is not optimal with a switched connection.

Important for single pipe heating! Always use thermostatic valve bodies with blue protection cap and stuffing box (gravity model).

Single pipe valve with immersion pipe

Technical description

HEIMEIER single pipe valve made out of gunmetal nickel-plated with immersion pipe for radiators with lateral single point connection. The valves consists of a single pipe valve lower part, immersion pipe (short or long version) and diaphragm plate.

Pipe connector G 3/4, with compression fittings for plastic, copper, precision steel, or multi-layer pipes.

For the HEIMEIER single pipe valve lower part, use only the accompanying, labeled HEIMEIER compression fittings (label e. g. 15 THE).

An almost completely consistent mass flow rate in the circular pipe is guaranteed by the special regulating cone.

When working at full capacity, the radiator is set at 35% of the mass flow rate in circuit.
Supply and return can be shut off, as a result of which the radiator is detachable without emptying the unit. The by-pass remains open, independent of the shutoff, so that circuit operation is not interrupted.

Note: The immersion pipes are available according to application in two different lengths. The long immersion pipe (thread reach 250 mm) is to be used when installing DIN, pipes and narrowtube radiators with more than 10 elements, otherwise use the short immersion pipe (thread reach 85 mm).

With both immersion pipes, the stuffing box is installed in the middle of the first element. When using plate and special radiators, a two chamber connection with a bore hole of Ø 11 mm must exist or the radiator connection must be installed in such a way so that the long immersion pipe can be fed in without a diaphragm plate.

Distributor and separation elements as well as the immersion pipe length are to be built according to the specifications of the respective radiator manufacturer.

The radiator can be easily disassembled by separating the immersion pipe in the screw connection.

The flow direction marked on the single pipe valve should be followed, since the flow through the radiator is not optimal with a switched connection.