Transfero T_

Pneumatex Transfero T_ is a precision pressure maintenance device up to 10 MW with pumps for heating, solar and chilled water systems. Its use is particularly recommended where high performance, compact design and precision are required. In the medium performance range with tight budgets, they can also be used as combination devices with integrated degassing and water make-up.

Informacije o proizvodima

Pressure maintenance systems up to 10 MW with pumps

Pneumatex Transfero T_ is a precision pressure maintenance device up to 10 MW with pumps for heating, solar and chilled water systems. Its use is particularly recommended where high performance, compact design and precision are required. In the medium performance range with tight budgets, they can also be used as combination devices with integrated degassing and water make-up.

Technical description – Control unit TecBox

Applications:

Heating, solar and chilled water systems.
For systems according to EN 12828, solar systems according to EN 12976, ENV 12977 with on-site excess temperature protection in case of power blackout.

Media:

Non-aggressive and non-toxic system media.
Addition of antifreeze agent up to 50%.

Pressure:

Min. admissible pressure, PSmin: 0 bar
Max. admissible pressure, PS: see Articles

Temperature:

Max. admissible temperature, TS: 70°C
Min. admissible temperature, TSmin: 0°C
Max. admissible ambient temperature, TU: 40°C
Min. admissible ambient temperature, TUmin: 5°C
Max. admissible temperature for water make-up, TW: 30°C (TP, TPV, TPV...P)

Accuracy:

Precision pressure maintenance ±0,2 bar.

Supply voltage:

230 V/50 Hz (T, TP, TV, TPV)
3x400/50 or 3x400/60 (TPV...P), see Articles.

Enclosure class:

IP 54 according to EN 60529

Material:

In essence: steel, brass and bronze

Function, Equipment, Features:

- BrainCube control. Self-optimising with memory function.
- Dynaflex operation. Elastic, speed-controlled operation (T, TP, TV, TPV). 2 pressure accumulator vessels for optimum pressure maintenance (TPV...P).
- Fillsafe water make-up monitoring with possibility to control water make-up through a Pleno P (T, TV). With contact water meter and a break tank type AB according to EN 1717, SVGW-tested (TP, TPV, TPV...P).
- Oxystop degassing of the system and make-up water under partial vacuum (TV, TPV).
- Protected isolating valves to the system.
- Variable installation next to the primary vessel.
- High quality metal cover (T, TP, TV, TPV, TPV...P) with handles (T, TP, TV, TPV).
- Including convoluted stainless steel hoses with seals for the connection of the primary vessel.

Transportation and storing:

In frostless, dry places.

Approvals:

CE-tested according to the requirements of the European Directives PED/DEP 97/23/EC, 2004/108/EC, 2006/95/EC.

Technical description – Expansion vessels

Applications:

Only together with Control unit TecBox.
See Applications under Technical description - Control unit TecBox.

Media:

Non-aggressive and non-toxic system media.
Addition of antifreeze agent up to 50%.

Pressure:

Min. admissible pressure, PSmin: 0 bar
Max. admissible pressure, PS: 2 bar

Temperature:

Max admissible temperature, TS: 120°C
Min. admissible temperature, TSmin: -10°C
Max. admissible bag temperature, TB: 70°C
Min. admissible bag temperature, TBmin: 5°C

Material:

Steel. Color beryllium.
Airproof butyl bag according to EN 13831 and Pneumatex internal standard.

Function, Equipment, Features

- Bag can be vented at the top, condensate drain at the bottom.
- Sinus ring for upright assembly (TU, TU...E). Feet for upright assembly (TG, TG...E).
- Airproof butyl bag (TU, TU...E, TG, TG...E), exchangeable (TG, TG...E).
- Endoscopic inspection opening for internal inspections (TU, TU...E). Two flange openings for internal inspections (TG, TG...E).

Transportation and storing:

In frostless, dry places.

Approvals:

CE design-tested according to PED/DEP 97/23/EC.

Warranty:

Transfero TU, TU...E: 5-year warranty for the vessel.
Transfero TG, TG...E: 5-year warranty for the airproof butyl bag.

Product Articles

Control unit TecBox, Transfero T – Articles

Transfero T .1

Precision pressure maintenance ±0,2 bar. 1 pump. 1 spill valve. Variable installation in front of or next to the primary vessel.
Connections: in (SE) Rp1, out (SA) Rp1, water make-up (SNS) Rp1/2, vessel (SG) R1.

Type
B
H
T

[kg]
PA
[kW]
SPL
[dB(A)]
EAN
Article No
8 bar (PS)
T 4.1
390
1000
490
29
0,6
55
7640148631259
811 1050
T 6.1
390
1000
490
33
1,1
55
7640148631266
811 1051
10 bar (PS)
T 8.1
500
1000
490
40
1,5
55
7640148631273
811 1052
T 10.1
500
1000
490
42
1,5
55
7640148631280
811 1053

T = Depth of the device

Transfero T .2

Precision pressure maintenance ±0,2 bar. 2 pumps. 2 spill valves. Switching is time and load dependant. Variable installation next to the primary vessel.
Connections: in (SE) Rp1 1/4, out (SA) Rp1 1/4, water make-up (SNS) Rp1/2, vessel (SG) R1 1/4.

Type
B
H
T

[kg]
PA
[kW]
SPL
[dB(A)]
EAN
Article No
8 bar (PS)
T 4.2
700
1000
400
49
1,1
55
7640148631297
811 1070
T 6.2
700
1000
400
57
2,2
55
7640148631303
811 1071
10 bar (PS)
T 8.2
800
1000
500
77
3
55
7640148631310
811 1072
T 10.2
800
1000
500
79
3
55
7640148631327
811 1073

T = Depth of the device

Accessories for control modules: Communication module. Master-Slave.

Accessories for pressure maintenance: Intermediate vessel. Datasheet Accessories.

Control unit TecBox, Transfero TP – Articles

Transfero TP .1

Precision pressure maintenance ±0,2 bar. Water make-up.
1 pump. 1 spill valve. Variable installation in front of or next to the primary vessel.
Connections: in (SE) Rp1, out (SA) Rp1, water make-up (SNS) G1/2, vessel (SG) R1.

Type
B
H
T

[kg]
PA
[kW]
SPL
[dB(A)]
EAN
Article No
8 bar (PS)
TP 4.1
390
1000
490
32
0,6
55
7640148631334
811 1060
TP 6.1
390
1000
490
36
1,1
55
7640148631341
811 1061
10 bar (PS)
TP 8.1
500
1000
490
43
1,5
55
7640148631358
811 1062
TP 10.1
500
1000
490
45
1,5
55
7640148631365
811 1063

T = Depth of the device

Transfero TP .2

Precision pressure maintenance ±0,2 bar. Water make-up.
2 pumps. 2 spill valves. Switching is time and load dependant. Variable installation next to the primary vessel.
Connections: in (SE) Rp1 1/4, out (SA) Rp1 1/4, water make-up (SNS) G1/2, vessel (SG) R1 1/4.

Type
B
H
T

[kg]
PA
[kW]
SPL
[dB(A)]
EAN
Article No
8 bar (PS)
TP 4.2
700
1000
400
52
1,1
55
7640148631372
811 1080
TP 6.2
700
1000
400
60
2,2
55
7640148631389
811 1081
10 bar (PS)
TP 8.2
800
1000
500
80
3
55
7640148631396
811 1082
TP 10.2
800
1000
500
82
3
55
7640148631402
811 1083

T = Depth of the device

Accessories for control modules: Communication module. Master-Slave.

Accessories for pressure maintenance: Intermediate vessel. Datasheet Accessories.

Control unit TecBox, Transfero TV – Articles

Transfero TV .1

Precision pressure maintenance ±0,2 bar. Degassing.
1 pump. 1 spill valve. Variable installation in front of or next to the primary vessel.
Connections: in (SE) Rp1, out (SA) Rp1, water make-up (SNS) Rp1/2, vessel (SG) R1.

Type
B
H
T

[kg]
PA
[kW]
SPL
[dB(A)]
EAN
Article No
8 bar (PS)
TV 4.1
390
1000
490
32
0,6
55
7640148631419
811 1000
TV 6.1
390
1000
490
36
1,1
55
7640148631426
811 1001
10 bar (PS)
TV 8.1
500
1000
490
43
1,5
55
7640148631433
811 1002
TV 10.1
500
1000
490
45
1,5
55
7640148631440
811 1003

T = Depth of the device

Transfero TV .2

Precision pressure maintenance ±0,2 bar. Degassing.
2 pumps. 2 spill valves. Switching is time and load dependant. Variable installation next to the primary vessel.
Connections: in (SE) Rp1 1/4, out (SA) Rp1 1/4, water make-up (SNS) Rp1/2, vessel (SG) R1 1/4.

Type
B
H
T

[kg]
PA
[kW]
SPL
[dB(A)]
EAN
Article No
8 bar (PS)
TV 4.2
700
1000
400
52
1,1
55
7640148631457
811 1030
TV 6.2
700
1000
400
61
2,2
55
7640148631464
811 1031
10 bar (PS)
TV 8.2
800
1000
500
80
3
55
7640148631471
811 1032
TV 10.2
800
1000
500
82
3
55
7640148631488
811 1033

T = Depth of the device

Accessories for control modules: Communication module. Master-Slave.

Control unit TecBox, Transfero TPV – Articles

Transfero TPV .1

Precision pressure maintenance ±0,2 bar. Water make-up. Degassing.
1 pump. 1 spill valve. Variable installation in front of or next to the primary vessel.
Connections: in (SE) Rp1, out (SA) Rp1, water make-up (SNS) G1/2, vessel (SG) R1.

Type
B
H
T

[kg]
PA
[kW]
SPL
[dB(A)]
EAN
Article No
8 bar (PS)
TPV 4.1
390
1000
490
35
0,6
55
7640148631495
811 1010
TPV 6.1
390
1000
490
39
1,1
55
7640148631501
811 1011
10 bar (PS)
TPV 8.1
500
1000
400
46
1,5
55
7640148631518
811 1012
TPV 10.1
500
1000
490
48
1,5
55
7640148631525
811 1013

T = Depth of the device

Transfero TPV .2

Precision pressure maintenance ±0,2 bar. Water make-up. Degassing.
2 pumps. 2 spill valves. Switching is time and load dependant. Variable installation next to the primary vessel.
Connections: in (SE) Rp1 1/4, out (SA) Rp1 1/4, water make-up (SNS) G1/2, vessel (SG) R1 1/4.

Type
B
H
T

[kg]
PA
[kW]
SPL
[dB(A)]
EAN
Article No
8 bar (PS)
TPV 4.2
700
1000
400
54
1,1
55
7640148631532
811 1040
TPV 6.2
700
1000
400
62
2,2
55
7640148631549
811 1041
10 bar (PS)
TPV 8.2
800
1000
500
82
3
55
7640148631556
811 1042
TPV 10.2
800
1000
500
84
3
55
7640148631563
811 1043

T = Depth of the device

Accessories for control modules: Communication module. Master-Slave.

Control unit TecBox, Transfero TPV...P – Articles

Transfero TPV .2 P

Precision pressure maintenance ±0,2 bar. Water make-up. Degassing.
2 pressure accumulator vessels for optimum pressure maintenance.
2 pumps. 2 spill valves. Switching is time and load dependant.
Connections: in (SE) Rp1 1/4, out (SA) Rp1 1/4, water make-up (SNS) G1/2, vessel (SG) R1 1/4.

Type
B
H
T

[kg]
PA
[kW]
U
[V/Hz]
SPL
[dB(A)]
EAN
Article No
16 bar (PS)
TPV 19.2 P
900
1300
900
139
6,0
3x400/50
<70
7640148631570
811 1045
TPV 19.2-60 P
900
1300
900
145
7,6
3x400/60
<70
7640148631587
811 1095

T = Depth of the device

Expansion vessels, Transfero TU/TU...E - Articles

Transfero TU

Primary vessel. Measuring foot for content measurement.
Including assembly kit for the water-side connection with 2 bar safety valve and ball valve for fast draining.

Type
VN
[l]
D
H

[kg]
S
SW
EAN
Article No
2 bar (PS)
TU 200
200
500
1335
36
R1 1/4
G3/4
7640148631594
713 1000
TU 300
300
560
1469
44
R1 1/4
G3/4
7640148631600
713 1001
TU 400
400
620
1528
62
R1 1/4
G3/4
7640148631617
713 1002
TU 500
500
680
1623
71
R1 1/4
G3/4
7640148631624
713 1003
TU 600
600
740
1633
78
R1 1/4
G3/4
7640148631631
713 1004
TU 800
800
740
2127
99
R1 1/4
G3/4
7640148631648
713 1005

VN = Nominal volume

Transfero TU...E

Secondary vessel.
Including assembly kit for the water-side connection, flexible hose and lock shield valve with ball valve for fast draining.

Type
VN
[l]
D
H

[kg]
S
SW
EAN
Article No
2 bar (PS)
TU 200 E
200
500
1335
33
R1 1/4
G3/4
7640148631655
713 2000
TU 300 E
300
560
1469
41
R1 1/4
G3/4
7640148631662
713 2001
TU 400 E
400
620
1528
59
R1 1/4
G3/4
7640148631679
713 2002
TU 500 E
500
680
1623
68
R1 1/4
G3/4
7640148631686
713 2003
TU 600 E
600
740
1633
75
R1 1/4
G3/4
7640148631693
713 2004
TU 800 E
800
740
2127
96
R1 1/4
G3/4
7640148631709
713 2005

VN = Nominal volume

Expansion vessels, Transfero TG/TG...E - Articles

Transfero TG

Primary vessel. Measuring foot for content measurement.
Including assembly kit for the water-side connection with 2 bar safety valve and ball valve for fast draining.

Type *
VN
[l]
D
H**

[kg]
S
SW
EAN
Article No
2 bar (PS)
TG 1000
1000
850
2191
280
R1 1/4
G3/4
7640148631716
713 1006
TG 1500
1500
1016
2340
360
R1 1/4
G3/4
7640148631723
713 1007
TG 2000
2000
1016
2839
640
R1 1/4
G3/4
7640148631730
713 1012
TG 3000
3000
1300
2940
800
R1 1/4
G3/4
7640148631747
713 1009
TG 4000
4000
1300
3585
910
R1 1/4
G3/4
7640148631754
713 1010
TG 5000
5000
1300
4230
1010
R1 1/4
G3/4
7640148631761
713 1011

VN = Nominal volume

*) Special vessel upon request.

**) Tolerance 0 /-100.

Transfero TG...E

Secondary vessel.
Including flexible hose for the water-side connection and lock shield valve with ball valve for fast draining.

Type *
VN
[l]
D
H**

[kg]
S
SW
EAN
Article No
2 bar (PS)
TG 1000 E
1000
850
2191
280
G1 1/4
G3/4
7640148631778
713 2006
TG 1500 E
1500
1016
2340
360
G1 1/4
G3/4
7640148631785
713 2007
TG 2000 E
2000
1016
2839
640
G1 1/4
G3/4
7640148631792
713 2012
TG 3000 E
3000
1300
2940
800
G1 1/4
G3/4
7640148631808
713 2009
TG 4000 E
4000
1300
3585
910
G1 1/4
G3/4
7640148631815
713 2010
TG 5000 E
5000
1300
4230
1010
G1 1/4
G3/4
7640148631822
713 2011

VN = Nominal volume

*) Special vessel upon request.

**) Tolerance 0 /-100.

Accessories for control modules

ComCube DCD

RS 485 interface for communicating with BrainCube, 6 digital inputs for the use of external volt free signals (NO), 9 volt free digital outputs, freely programmable; all outputs can be inversed. Wall mounted, fixing elements for cable management.

Type
B
H
T

[kg]
PA
[kW]
EAN
Article No
DCD
270
230
260
0,5
0,1
7640148638715
814 1000

T = Depth of the device

ComCube DCA

2 separated analoge outputs 4-20 mA for connection to BMS, isolation voltage 2.5 kVAC. All cabeling inside the casing, wall mounted.

Type
B
H
T

[kg]
PA
[kW]
EAN
Article No
DCA
190
260
180
0,5
0,1
7640148638739
814 1010

T = Depth of the device

Master-Slave DMS 2

Parallel operation of 2 Transfero T_
Including assembly kit with 1 safety valve for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels.

Type
EAN
Article No
DMS 2 T
7640148638760
814 1021

Master-Slave DMS 3

Parallel operation of 3 Transfero T_
Including assembly kit with 2 safety valves for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels.

Type
EAN
Article No
DMS 3 T
7640148638784
814 1026

Master-Slave DMS 4

Parallel operation of 4 Transfero T_
Including assembly kit with 3 safety valves for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels.

Type
EAN
Article No
DMS 4 T
7640148638807
814 1031

Aminacije

Koristite ovu interaktivnu animaciju za simulaciju učinaka naših inovativnih proizvoda u vašem HVAC sustavu. Kliknite na gumb za početak!

Slike

Download all

Crteži

Download all

2D/3D

Download all

Tehničke specifikacije

Instalacijske upute

Zakonski dokumenti

Filmovi/Vježba